Presentation
Memory-Efficient and Real-Time SPAD-based dToF Imaging with Spatial and Statistical Correlation
DescriptionRecently, Single Photon Avalanche Diode (SPAD)based direct time-of-flight (dToF) imaging systems have emerged as a popular solution for depth measurement due to their high speed and sensitivity features. Existing SPAD-based dToF performs depth measurements through the depth histogram accumulation method. However, in order to achieve high spatial resolution and measurement accuracy, the depth histogram accumulation results in large memory overhead and long accumulation latency when the signal-to-background ratio (SBR) is low. To overcome these two challenges, we propose a novel sensor-side SPAD-based dToF imaging system from both algorithm and hardware perspectives. Extensive experiments show that our proposed system reaches SOTA.
Event Type
Research Manuscript
TimeThursday, July 13th3:40pm - 3:55pm PDT
Location3004, 3rd Floor
Cloud
Design
Design of Cyber-physical Systems and IoT